Earthing And Lightning Protection

DESIGN PHILOSOPHY

We are specialists in the design, supply and installation of the lightning protection system, earthing system and surge protection systems in association with renowned international brand FURSE – ABB Group. Our lightning protection system is designed as per IS/TEC specifications and every product comes with test certifications to prove its utility in protecting the consumers at all times.

It is a highly dependable lightning protection system that provides lightning protection extrernally (to the structure), and includes effective earthing and surge protection for the electronic devices.

It is this capability that makes it a Total Solution for Earthing and lightning protection. We provide the most comprehensive and potent protection against the danger of lightning. It safeguards lives and ensures continuous, smooth operation of vital electronic systems.

This process of lightning protection has been endorsed fully by IS/IEC 62305 Standard.

We offer the following systems and services:


1. Lightning protection system

  • • Team of experienced engineers
  • • Engineered designs customized to client specifications
  • • Risk assessment complying with latest standards

2. Soil resistivity surveys

  • • Experienced surveyors
  • • Key to creating effective earthing system
  • • Multiple readings taken to ensure safe and accurate designs

3. Earthing design

  • • Detailed design to meet the desired resistance to earth value in line with the standards

4. Testing & Certification

  • • Verification of earthing design through measurement
  • • Experienced team of engineers who are well-versed electrode testing

  • 5. Compliance, now & in the future
    Furse designs meet all recognized standards.

  • • IS/IEC 62305 Protection against lightning
  • • NFPA 780 Standard for the installation of lightning protection systems
  • • IEEE Std 80:2000 IEEE Guide for safety in AC substation grounding
  • • BS7430:2011 Earthing of Electrical installation
  • • ENA TS 41-24 Guidelines for the design, installation, testing & maintenance of main earthing systems in substations.
  • • BS EN 50522:2010 - Earthing of power installations exceeding 1.k Vac
  • • S34 – Assessment of the rise of earth potential at substation site

Post Thumbnail

The Gas fired Models Feature:

  • Models available on Natural Gas and LPG operation.
  • Resettable Thermal Switch—Proven and reliable bimetallic switch preventsburner and pilot operation in case of ongoing flammable vapor burn inside ofthe combustion chamber or restricted air flow.
  • • Piezo Igniter—Easy and quick lighting of the pilot burner by push button.
  • Pedestal Base—Rugged and durable base allows easy transport andpositioning, while providing corrosion resistant contact with floor.
  • • Maintenance Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions.
  • • Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner.
  • • Factory Installed Hydrojet Total Performance System—Cold water inlet sediment reducing device helps prevent sediment build up in tank and increases first hour delivery of hot water.
  • • Vitraglas® Lining—Bradford White water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating that provides a tough interior surface for our hot water tanks.
  • • Fully Automatic Controls—Automatic temperature selection at your fingertips. Built-in energy cut-off switch prevents abnormally high water temperature for extra safety. Built-in gas pressure regulation.
  • • 1" Non-CFC Foam Insulation—Covers the sides and top of tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiency and jacket rigidity.
  • • Water Connections—3⁄4" NPT factory installed true dielectric fittings extendwater heater life and eases installation.
  • • Factory Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation.
  • • Protective Magnesium Anode Rod—Provides added protection against
  • • Corrosion for long trouble-free service.
  • • Flue Baffle—Maximizes the amount of heat absorbed by the tank and
  • • Reduces heat loss during standby periods.
  • • Steel Tank—Heavy gauge steel automatically formed, rolled and welded.
  • • T&P Relief Valve—Included.
  • • Brass Drain Valve.

STELT

STELT condensing boiler, made from AISI 316 Ti stainless steel with reverse flame combustion chamber able to produce hot water at a maximum temperature of 110 °C. Connected to pressure jet burners operating on gaseous fuels. Some of the product's main features are related below:

inclined boiler body for condensate drainage support

large cylindrical combustion chamber with reversed flame manufactured from AISI 316 Ti stainless steel, TIG pulse welded, able to withstand acid condensate attack.

stainless steel gas passages with special profiles, placed around the combustion chamber in order to extend flue gas development and consequently increase heat exchange and increase boiler efficiency (obtaining low NOx emissions in conjunction with Low NOx burners)

heat exchange surfaces made from AISI 316 Ti stainless steel, welded with TIG method, consisting of stainless plates characterized by a particular corrugated shape being able to increase heat exchange surface, and facilitate droplet condensate formation allowing adequate drainage.

welded using TIG, MIG and plasma procedures, methods that guarantee stainless steel main mechanical characteristics, without sacrificing corrosion resistance to acid condensation.

flanged flow connection and two system return connections for boiler differential input and ensuring minimum possible temperature to take advantage of condensing benefits even in case of medium-high temperature returns.

flue gas chamber able to collect resultant condensate and discharge it through a water trap connected to a neutralizer (where provided) to the waste water drainage system.

burner mounting plate, for attaching pressure jet burners for gaseous fuels use.

heat dispersion surface insulation with thick glass wool mattress, protected with steel varnished panels that can be easily removed

front door with reversible steel sheet opening thermally insulated with ceramic fiber.


Standard equipment:

complete insulating casing

  • Ancillaries Code
  • Acid condensate Neutralizer system
  • Neutralizer 81020001
  • Neutralizer with pump 81020002
  • Control panels
  • Thermostatic control panel QCOND01ELMCE
  • Features can be seen in “Thermostatic control panels section”
  • Control panels
  • Thermostatic control panel QCOND01ELMCE
  • Features can be seen in “Thermostatic control panels section”
  • Boiler management
  • control panel QETERM01RU2*
  • System management
  • control panel
  • QETERM02
  • For characteristics and other ancillaries see “ system” section
  • This code refers to markets of: Russia, Belarus, Ukraine, Georgia and Kazakhstan
  • Product CE marked according to the European
  • Directives in force:
  • Control panels
  • Thermostatic control panel QACCBT01ELMCE
  • Features can be seen in “Thermostatic control panels section”

WALL M BOILERS

WALL condensing boiler, with both European and Italian Patent designed by ICI Caldaie for high power in contained spaces.

Particular boiler geometry together with large heat exchange surfaces allow considerable flue gas temperature reduction resulting in 109% efficiency achievement (referring to PCI and Temp. Delivery/Return 50/30 °C). Latest concept burner, 20% to 100% Nominal Power pre-mix flame modulation. Reduced environmental impact achieved by under 10 ppm NOx emissions.

Some of the product’s main features are related below:

  • large Combustion Chamber, single pass flame with dry and low thermal load reversal chamber
  • crossed groove, W stainless steel, high efficiency flue gas duct
  • reverse double slope structure for condensate integral recovery, high and low temperature double return.
  • parts in contact with combustion products - combustion chamber and gas plates - are entirely made out of AISI 316 Ti titanium stabilized stainless steel.- cascade operation in advance setup with 125 kW and 150 kW modules having a maximum of 4 boilers, reaching a maximum power of 600 kW reached using condensing operation.
  • modulating gas burners with total gas pre-mix, heat radiating cylindrical body, low NOx emission (below 10 ppm)
  • 20 to 100% maximum power adjustment.
  • 109% COP (coefficient of performance), 50/30°C boiler water temperature
  • each module is equipped with a digital control panel for burner modulation management and climatic compensation for fluctuating temperature.
  • AISI 316 L STAINLESS STEEL external casing, internally insulated with high density, thick mineral wool mattress.
  • IPX4D protection.
  • Ancillaries Code
  • Acid condensate Neutralizer system
  • Neutralizer 81020001
  • Neutralizer with pump 81020002
  • System management control panel QETERM02
  • For characteristics and other ancillaries see “ system” section
  • WALL model to be assemled
  • WALL M model supplied assembled on its base
Standard equipment:
  • flow Manifold, high-low temperature dual return
  • INAIL security devices
  • combustion gas collector
  • gas collector
  • cascade climatic regulator
  • operational with methane and GPL
  • flow Manifold probe (in presence of 2 or more modules)
  • control panel equipped with:
  • main switch
  • manual or Automatic burner operation switch
  • manual or Automatic burner operation switch
  • control thermostat
  • safety thermostat
  • thermometer
  • microprocessor board
  • boiler probe
  • external probe (only for master control panel)
  • GSM modem
  • Product CE marked according to the European
  • Directives in force:
  • 92/42/CE - Efficiency (applicable up to 400 kW)
  • 2009/142/CE - Gas
  • 2014/30/UE - Electromagnetic Compatibility
  • 2014/35/UE - Low Voltage